FN 3410 ECOsine™ 50Hz Passive Harmonic Filters
- The industry standard for 6-pulse rectifiers and motor drives
- The most compact 5% THID filter available
- Excellent behavior under partial load conditions
- Filters for diode rectifiers
- Frequency: 50 Hz
- Harmonic mitigation: THID < 5%
- Rated Power: 4 to 200 kW
- Voltage: 380 to 500 V
FN 3410HV ECOsine™ 50Hz Passive Harmonic Filters for 690V
- The industry standard for 6-pulse rectifiers and motor drives
- The most compact 5% THID filter available
- Excellent behavior under partial load conditions
- Filters for diode rectifiers
- Frequency: 50 Hz
- Harmonic mitigation: THID < 5%
- Rated Power: 7.5 to 250 kW
- Voltage: 690 V
FN 3411 ECOsine™ 50Hz Passive Harmonic Filters
- The industry standard for 6-pulse rectifiers and motor drives
- Excellent behavior under partial load conditions
- Filters for thyristor (SCR) rectifiers
- Frequency: 50 Hz
- Harmonic mitigation: THID depending upon firing angle
- Rated Power: 4 to 200 kW
- Voltage: 380 to 500 V
FN 3412 ECOsine™ 60Hz Passive Harmonic Filters
- The industry standard for 6-pulse rectifiers and motor drives
- The most compact 5% THID filter available
- Excellent behavior under partial load conditions
- Filters for diode rectifiers
- Frequency: 60 Hz
- Harmonic mitigation: THID < 5%
- Rated Power: 5 to 250 HP
- Voltage: 380 to 480 V
FN 3413 ECOsine™ 60Hz Passive Harmonic Filters
- The industry standard for 6-pulse rectifiers and motor drives
- Excellent behavior under partial load conditions
- Filters for thyristor (SCR) rectifiers
- Frequency: 60 Hz
- Harmonic mitigation: THID depending upon firing angle
- Rated Power: 5 to 250 HP
- Voltage: 380 to 480 V
(30A to 100A UL recognized / 200A to 300A UL listed)
FN 3420 ECOsine™ Active Harmonic Filters (3-wire)
- Programmable harmonics mitigation, power factor correction, load balancing
- Ultra-fast electronics result in a response time of less than 300µs
- Adapts to changing network topologies instantly
- Filters for up to 480V 3-wire networks
- Compensation current: 30 to 300 A
- Frequency: 47 to 63 Hz
- Harmonic mitigation: THID < 5%,THID adjustable
- Voltage: 200 to 480 V
FN 3430 ECOsine™ Active Harmonic Filters (4-wire)
- Programmable harmonics mitigation, power factor correction, load balancing
- Ultra-fast electronics result in a response time of less than 300µs
- Adapts to changing network topologies instantly
- Filters for 400V 4-wire networks
- Compensation current: 30 to 300 A
- Frequency: 47 to 63 Hz
- Harmonic mitigation: THID < 5%,THID adjustable
- Voltage: 380 to 415 V
(on request)
Compact and user-friendly combination of transformer and reactor
- Combination of insulation, step-up or step-down transformer and smoothing- or filter-reactor
- Possibility to customize most electrical and mechanical parameters
- Reduction in overall weight and volume
- Reduction in installation time
- Simplification of the power structure
- Reduction in total cost of ownership
- Frequency: 50 to 60 Hz
- Harmonic mitigation: All
(C-UL-US in Vorbereitung)
RWK 212 Three-phase line reactor for motor drive applications
- Reduction of mains harmonics
- Reduction of commutation notches
- Protection of motor drive electronics
- Limitation of inrush currents
- Improvement of true power factor
- Frequency: 50 to 60 Hz
- Harmonic mitigation: THID appr. 40%
- Impedance: 4% @ 400VAC, 50Hz, Nennstrom
- Motor power: 1.5 to 630 kW
- Rated Current: 4 to 1100 A
- Voltage: ≤ 500 V
FN 5020 Sine wave output filter for high-speed motor drives
- Smoothing of PWM drive output voltages
- Increased service life of expensive high-speed motors
- Reduction of audible motor noise
- Improvement of system reliability
- Production up-time for mission critical applications
- Harmonic mitigation: All
- Motor cable length: ≤200m
- Motor frequency: 0 to 600 Hz
- Motor power: 15 to 75 kW
- Rated Current: 25 to 120 A
- Switching Frequency: 6 to 15 kHz
- Voltage: 0 to 500 V
FN 5030 Add-on sine wave output filter module for common-mode voltage improvement
- Additional module for use with FN 5020 sine wave filters only
- Reduction of common-mode interferences on motor cables
- Improvement of EMC environment
- Elimination of motor bearing damages
- Possibility to use very long unshielded motor cables
- Improvement of system reliability
- Harmonic mitigation: All
- Motor cable length: ≤1000m
- Motor frequency: 0 to 600 Hz
- Motor power: 15 to 75 kW
- Rated Current: 25 to 120 A
- Switching Frequency: 6 to 15 kHz
- Voltage: 0 to 500 V
(UL US Listed in Vorbereitung)
FN 5040 / FN 5045 LC sine wave filter for motor drives
- Smooth sine wave without voltage peaks
- Motor protection against pulse pattern stress
- Improvement of system reliability
- Simple to install
- Harmonic mitigation: All
- Motor cable length: ≤2000m
- Motor frequency: 0 to 70 Hz
- Motor power: 1.1 to 630 kW
- Rated Current: 4.5 to 1200 A
- Switching Frequency: 2 to 12 kHz
- Voltage: 0 to 500 V
FN 510 Output filter for motor drives
- Reduction of drive output voltage dv/dt
- Restriction of overvoltages on motor cables
- Reduction of motor temperature
- Increase of motor service life
- Improvement of system reliability
- Harmonic mitigation: All
- Motor cable length: ≤80m
- Motor frequency: 0 to 400 Hz
- Motor power: 1.5 to 30 kW
- Rated Current: 4 to 66 A
- Switching Frequency: 2 to 16 kHz
- Voltage: 380 to 500 V
FN 530 Sine wave and EMC output filter for motor drives with a voltage dc link
- Smoothing of PWM drive output voltage
- Efficient motor protection
- Reduction of common-mode interferences on motor cables
- Improvement of EMC environment
- Elimination of motor bearing damages
- Possibility to use very long unshielded motor cables
- Improvement of system reliability
- Harmonic mitigation: All
- Motor cable length: ≤1000m
- Motor frequency: 0 to 200 Hz
- Motor power: 1.5 to 7.5 kW
- Rated Current: 4 to 16 A
- Switching Frequency: 6 to 20 kHz
- Voltage: 0 to 520 V
RWK 305 Three-phase dv/dt reactor for efficient motor protection
- Reduction of drive output voltage dv/dt
- Reduction of motor temperature
- Increase of motor service life
- Compact and economic open frame design
- Standard catalog reactors
- UL rated materials used
- Harmonic mitigation: All
- Motor cable length: ≤50m
- Motor frequency: 0 to 60 Hz
- Motor power: 1.5 to 630 kW
- Rated Current: 4 to 1100 A
- Switching Frequency: 2 to 16 kHz
- Voltage: 380 to 500 V