Products
Products: 94
Custom magnetic components for rail technology
- Transformers, inductors and filters for rolling stock
- Wayside traction power transformers
- Built according to the highest requirements for rail
- Tough mechanical constructions for outdoor use
- Advanced calculation, design and simulation tools
- IRIS certified
Custom reactors and filters
- Special reactors for e.g. PV inverters
- Special dv/dt filters for e.g. wind turbines
- Special sine wave filters for e.g. motor drives
- Special LCL filters for e.g. energy re-generation
- Compact combinations of transformer and reactor
- Engineered to application requirements or specs
FN 402 Low cost PCB filter
- Rated currents from 0.5 to 6.5A
- Compact PCB-mountable design
- Very low profile
- Optional medical versions (B type)
- Attenuation performance: standard
- Leakage current: 373 µA
- Leakage current (B types): 2 µA
- Operating frequency: dc to 400 Hz
- Rated Current: 0.5 to 6.5 A
- Voltage: ≤ 250 V
FN 406 Ultra compact EMC filter
- Rated currents from 0.5 to 8.4A
- Aluminium case
- Very compact PCB-mountable design
- Low profile
- Optional medical versions (B type)
- Attenuation performance: standard
- Leakage current: 373 µA
- Leakage current (B types): 2 µA
- Operating frequency: dc to 400 Hz
- Rated Current: 0.5 to 8.4 A
- Voltage: ≤ 250 V
IL13 Power cord with Locking System for IEC inlet filters with C14 inlet
- Locking system for tandardized IEC C14 inlet
- No accidental disconnection
- Fits any Schaffner IEC C14 inlet filter
- Retrofit for any IEC C14 inlet
- Various power line plugs for international usage
- Standard and hospital grade plugs available
- Color: black
- Connector line side: C14; CEE7/VII; BS1363; NEMA5-15; SEV1011; JIS8303
- Connector load side: C13 with IEC lock
- Frequency: 50/60 Hz
- Length: 2 m
- Operating frequency: dc to 60 Hz
- Rated Current: 10 A
- Voltage: ≤ 250 V
IL19 Power cord with Locking System for IEC inlet filters with C20 inlet
- Power cord with locking system for IEC inlets
- No accidental disconnection
- Fits any Schaffner IEC C20 inlet filter
- Retrofit for any electronic equipment with IEC C20 inlet
- Various power line plugs for international usage
- Color: black
- Connector line side: C20; CEE7/VII; BS1363; NEMA5-15
- Connector load side: C19 with IEC Lock
- Rated Current: 16 A
- Voltage: ≤ 250 V
FN 9222 General performance IEC inlet filter
- Excellent performance/size ratio
- Optional medical versions (B type)
- Snap-in versions (S and S1 type)
- Hot inlet versions (HI type)
- Optional overvoltage protection (Z type)
- Attenuation performance: standard
- Leakage current: 373 µA
- Leakage current (B types): 2 µA
- Operating frequency: dc to 400 Hz
- Rated Current: 1 to 20 A
- Voltage: ≤ 250 V
- Compliant IEC/EN 60601-1
(CQC approval pending)
FN 9222E General performance IEC inlet filter with earth line choke
- Rated currents up to 15A
- Excellent performance/size ratio
- Integrated earth line choke
- Optional medical versions (B type)
- Snap-in versions (S and S1 type)
- Optional wide mounting flanges
- Attenuation performance: standard
- Leakage current: 373 µA
- Leakage current (B types): 2 µA
- Operating frequency: dc to 400 Hz
- Rated Current: 1 to 15 A
- Voltage: ≤ 250 V
- Compliant IEC/EN 60601-1
FN 9226 HF performance IEC inlet filter
- Faston connection
- Optional PCB through hole connection
- Good HF coupling to the equipment housing
- Optional medical versions (B type)
- Attenuation performance: standard
- Leakage current: 373 µA
- Leakage current (B types): 2 µA
- Operating frequency: dc to 400 Hz
- Rated Current: 1 to 10 A
- Voltage: ≤ 250 V
(CQC approval pending)
FN 9233 High performance IEC inlet filter
- Excellent attenuation performance
- Optional earth line choke
- Optional medical versions (B type)
- Snap-in versions (S and S1 type)
- Hot inlet versions (HI type)
- Attenuation performance: standard, high
- Leakage current: 373 µA
- Leakage current (B types): 2 µA
- Operating frequency: dc to 400 Hz
- Rated Current: 1 to 15 A
- Voltage: ≤ 250 V
- Compliant IEC/EN 60601-1
(CQC approval pending)
FN 9233E High performance IEC inlet filter with earth line choke
- Excellent attenuation performance
- Integrated earth line choke
- Optional medical versions (B type)
- Snap-in versions (S and S1 type)
- Hot inlet versions (HI type)
- Attenuation performance: high, very high
- Leakage current: 373 µA
- Leakage current (B types): 2 µA
- Operating frequency: dc to 400 Hz
- Rated Current: 1 to 15 A
- Voltage: ≤ 250 V
- Compliant IEC/EN 60601-1
(CQC approval pending)
FN 9244 Excellent performance IEC inlet filter
- Superior attenuation performance
- Optional earth line choke
- Optional medical versions (B type)
- Snap-in versions (S and S1 type)
- Hot inlet versions (HI type)
- Attenuation performance: very high
- Leakage current: 373 µA
- Leakage current (B types): 2 µA
- Operating frequency: dc to 400 Hz
- Rated Current: 1 to 15 A
- Voltage: ≤ 250 V
- Compliant IEC/EN 60601-1
(CQC approval pending)
FN 9244E Excellent performance IEC inlet filter with earth line choke
- Superior attenuation performance
- Integrated earth line choke
- Optional medical versions (B type)
- Snap-in versions (S and S1 type)
- Hot inlet versions (HI type)
- Attenuation performance: very high
- Leakage current: 373 µA
- Leakage current (B types): 2 µA
- Operating frequency: dc to 400 Hz
- Rated Current: 1 to 15 A
- Voltage: ≤ 250 V
- Compliant IEC/EN 60601-1
FN 9260 General purpose power entry module with fuses
- Rated currents up to 10A
- For one or two fuses
- Optional safety version (A type)
- Optional medical versions (B type) according to IEC/EN 60601-1
- Snap-in versions (S type)
- Attenuation performance: standard
- Leakage current: 373 µA
- Operating frequency: dc to 400 Hz
- Rated Current: 1 to 10 A
- Voltage: ≤ 250 V
(CQC approval pending)
FN 9263 General purpose power entry module with mains switch
- Rated currents up to 10A
- 1-pole rocker switch
- Snap-in versions (S and S1 type)
- Compact to fit 1U rack size
- Attenuation performance: standard
- Frequency: 50 to 400 Hz
- Leakage current: 373 µA
- Operating frequency: dc to 400 Hz
- Rated Current: 1 to 10 A
- Voltage: ≤ 250 V
(CQC approval pending)
FN 9264 Compact power entry module
- Compact size
- Rated currents up to 10A
- Complies with IEC/EN 60601
- High quality 2-pole rocker switch
- Good attenuation performance
- Snap-in versions (S type)
- Attenuation performance: high
- Frequency: 50 to 400 Hz
- Leakage current: 373 µA
- Operating frequency: dc to 400 Hz
- Rated Current: 1 to 10 A
- Voltage: ≤ 250 V
FN 280 Compact filtered power entry module
- Rated currents up to 10A
- Single or dual-fuse holder
- Fuses Ø5 x 20mm
- 2-pole rocker switch
- General purpose application
- Optional earth line choke (E type)
- Optional medical versions (B type)
- Attenuation performance: standard
- Frequency: 50 to 400 Hz
- Leakage current: 373 µA
- Leakage current (B types): 2 µA
- Operating frequency: dc to 400 Hz
- Rated Current: 1 to 10 A
- Voltage: ≤ 250 V
FN 370 Versatile filtered power entry module
- Rated currents up to 6A
- Single or dual-fuse holder
- Fuses Ø6.3 x 32mm or Ø5 x 20mm
- Voltage selector 100/120/230/240V
- General purpose application
- Optional medical versions (B type)
- Attenuation performance: standard
- Leakage current: 373 µA
- Leakage current (B types): 2 µA
- Operating frequency: dc to 400 Hz
- Rated Current: 2 to 6 A
- Voltage: ≤ 250 V
FN 380 Versatile filtered power entry module
- Single or dual-fuse holder
- Fuses Ø6.3 x 32mm Ø5 x 20mm
- 2-pole rocker switch
- General purpose application
- Optional medical versions (B type)
- Attenuation performance: standard
- Frequency: 50 to 400 Hz
- Leakage current: 373 µA
- Leakage current (B types): 2 µA
- Operating frequency: dc to 400 Hz
- Rated Current: 2 to 6 A
- Voltage: ≤ 250 V
FN 390 Versatile filtered power entry module
- For one or two fuses
- Fuses Ø6.3 x 32mm or Ø5 x 20mm
- 2-pole rocker switch
- Voltage selector
- Optional earth line choke (E type)
- Attenuation performance: high
- Frequency: 50 to 400 Hz
- Leakage current: 560 to 797 µA
- Operating frequency: dc to 400 Hz
- Rated Current: 1 to 10 A
- Voltage: ≤ 250 V
(CQC, approval pending)
FN 9280 Ultra compact and versatile filtered single stage power entry module
- Single stage filter
- Ultra compact design
- Rated currents up to 10A
- dual-fuse holder
- Fuses Ø5x20mm
- 2-pole rocker switch
- Good attenuation performance
- Faston or spring cage terminals
- Attenuation performance: high
- Frequency: 50 to 400 Hz
- Leakage current medical (B types): < 5 µA
- Leakage current standard: < 500 µA
- Operating frequency: dc to 400 Hz
- Rated Current: 1 to 10 A
- Voltage: ≤ 250 V
(CQC, approval pending)
FN 9290 Ultra compact and versatile filtered dual stage power entry module
- Dual stage filter
- Ultra compact design
- Rated currents up to 10A
- Dual fuse holder
- 2-pole rocker switch
- Good attenuation performance
- Faston or spring cage terminals
- Attenuation performance: very high
- Frequency: 50 to 400 Hz
- Leakage current medical (B types): < 5 µA
- Leakage current standard: < 500 µA
- Operating frequency: dc to 400 Hz
- Rated Current: 1 to 10 A
- Voltage: ≤ 250 V
(UL for 600VDC; ENEC for 850V)
FN 2200 DC EMC/EMI filter for photovoltaic inverters
- Reduces conducted emissions towards the solar panel
- Reduces the probability of EMI radiation off the solar panel
- Helps to prevent pre-mature panel aging because of HF leakage currents
- Helps to meet international EMC regulations for the entire PV system
- Most compact standard solution in the industry, optionally available without capacitors to ground (B types)
- New: up to 2300A
- Attenuation performance: high, very high
- Rated Current: 25 to 2300 A
- Voltage: ≤ 1200 V
FN 2010 General purpose EMC/EMI filter
- General purpose filtering performance
- Optional medical versions (B type)
- Optional safety versions (A type)
- Attenuation performance: standard
- Leakage current: 0.74 mA
- Leakage current (A types): 0.074 mA
- Leakage current (B types): 0.002 mA
- Operating frequency: dc to 400 Hz
- Rated Current: 1 to 60 A
- Voltage: ≤ 250 V
FN 2020 General Purpose EMI Filter
- Rated currents from 1 to 60A
- High differential-mode attenuation
- Optional medical version (B type)
- Optional safety version (A type)
- Attenuation performance: standard
- Leakage current: 0.74 mA
- Leakage current (A types): 0.074 mA
- Leakage current (B types): 0.002 mA
- Operating frequency: dc to 400 Hz
- Rated Current: 1 to 60 A
- Voltage: ≤ 250 V
FN 2030 General purpose EMC/EMI filter with high attenuation performance
- Rated currents from 1 to 30A
- High performance filter attenuation
- High differential-mode attenuation
- Optional medical versions (B type)
- Optional safety versions (A type)
- Optional overvoltage protection (Z type)
- Attenuation performance: standard, high
- Leakage current: 0.34 to 0.87 mA
- Leakage current (A types): 0.074 mA
- Leakage current (B types): 0.002 mA
- Operating frequency: dc to 400 Hz
- Rated Current: 1 to 30 A
- Voltage: ≤ 250 V
FN 2410 / FN 2412 Single and two-phase EMC/EMI filters for industrial electronics
- Excellent filter performance for applications with high interference levels
- Fast and comfortable snap-in installation on popular TS 35 DIN-rails up to 45A
- Industrial grade terminal blocks for unsurpassed electrical safety
- Attenuation performance: high, very high
- Leakage current: 3.4 mA
- Operating frequency: dc to 400 Hz
- Rated Current: 8 to 100 A
- Voltage: ≤ 250 V
- Voltage VAC (H types): 520 VAC
FN 2450 Safe and ergonomic EMC/EMI filter with very low leakage current
- Light weight plastic enclosure design
- Very low filter leakage current
- Hinged safety covers
- Embedded filter terminals
- Different performance levels
- Environmental friendly design without potting compound
- Attenuation performance: high
- Leakage current (B types): 0.002 mA
- Leakage current (F types): 0.5200 mA
- Leakage current (G types): 0.7300 mA
- Operating frequency: dc to 400 Hz
- Rated Current: 6 to 20 A
- Voltage: ≤ 250 V
FN 350 Single-phase EMC/EMI filter for motor drives
- Compact filter solution for single-phase motor drive applications
- Industrial grade safety terminal blocks
- Designed to meet EN 55011/14/22
- Compliant with IEC 60950
- Attenuation performance: standard, high
- Leakage current: 4.9 to 11 mA
- Operating frequency: dc to 400 Hz
- Rated Current: 8 to 55 A
- Voltage: ≤ 250 V
FN 2060 Multi-stage general purpose EMC/EMI filter
- High differential and common-mode attenuation
- Optional medical versions (B type)
- Optional safety versions (A type)
- Attenuation performance: standard, high
- Leakage current: 0.734 to 0.867 mA
- Leakage current (A types): 0.074 mA
- Leakage current (B types): 0.002 mA
- Operating frequency: dc to 400 Hz
- Rated Current: 1 to 30 A
- Voltage: ≤ 250 V
FN 2070 Multi-stage performance EMC/EMI filter
- High differential and common-mode attenuation
- High frequency attenuation
- Optional medical versions (B type)
- Optional safety versions (A type)
- Attenuation performance: high
- Leakage current: 0.734 to 0.867 mA
- Leakage current (A types): 0.074 mA
- Leakage current (B types): 0.002 mA
- Operating frequency: dc to 400 Hz
- Rated Current: 1 to 36 A
- Voltage: ≤ 250 V
FN 2080 Multi-stage high performance EMC/EMI filter
- High differential and common-mode attenuation
- Good low frequency attenuation
- Optional medical versions (B type)
- Optional safety versions (A type)
- Attenuation performance: high
- Leakage current: 0.734 mA
- Leakage current (A types): 0.074 mA
- Leakage current (B types): 0.002 mA
- Operating frequency: dc to 400 Hz
- Rated Current: 1 to 16 A
- Voltage: ≤ 250 V
FN 2090 Multi-stage EMC/EMI filter with excellent attenuation performance
- Rated currents from 1 to 30A
- Two-stage filter
- Very high differential and common-mode attenuation
- Optional medical versions (B type)
- Optional safety versions (A type)
- Optional overvoltage protection (Z type)
- Attenuation performance: very high
- Leakage current: 0.5 to 1.02 mA
- Leakage current (A types): 0.08 mA
- Leakage current (B types): 0.002 mA
- Operating frequency: dc to 400 Hz
- Rated Current: 1 to 30 A
- Voltage: ≤ 250 V
FN 2360 High performance EMC/EMI filter
- Exceptional differential and common-mode attenuation
- UL-rated materials
- Optional medical versions (B type)
- Attenuation performance: high
- Leakage current: 0.52 to 0.7 mA
- Leakage current (B types): 0.004 mA
- Operating frequency: dc to 400 Hz
- Rated Current: 3 to 6 A
- Voltage: ≤ 250 V
FN 2415 Single-phase EMC/EMI filter for the control line of equipment
- Filter for the control line of complex equipment and machinery
- Ensures the interference-free operation of the control unit / PLC
- Improves the immunity and reliability of the entire system
- Compact EMC filter design with minimum space requirement
- Attenuation performance: high, very high
- Leakage current: 9.4 mA
- Operating frequency: dc to 60 Hz
- Rated Current: 6 to 16 A
- Voltage: ≤ 250 V
FN 343 Performance EMC/EMI filter
- Dual-stage filter
- Compact housing
- Integrated earth line choke
- Attenuation performance: standard, high
- Leakage current: 0.734 to 0.867 mA
- Leakage current (A types): 0.074 mA
- Leakage current (B types): 0.002 mA
- Operating frequency: dc to 400 Hz
- Rated Current: 1 to 10 A
- Voltage: ≤ 250 V
FN 685 High-power performance EMC/EMI filter
- Excellent differential and common-mode attenuation
- Attenuation performance: high, very high
- Leakage current: 0.734 to 0.867 mA
- Leakage current (A types): 0.074 mA
- Leakage current (B types): 0.002 mA
- Operating frequency: dc to 400 Hz
- Rated Current: 10 to 36 A
- Voltage: ≤ 250 V
FN 700Z Three-stage EMC/EMI filter
- Rated currents from 6 to 20A
- IEC inlet for 6 and 10A versions
- TEMPEST/NEMP
- Up to 3GHz attenuation
- High surge voltage protection
- Attenuation performance: high, very high
- Leakage current: 440 to 2600 µA
- Operating frequency: dc to 400 Hz
- Rated Current: 6 to 20 A
- Voltage: ≤ 250 V
(UL/CSA: up to 180A (ex. -180-07), HV and HVIT up to 600VAC)
FN 258 Book-style EMC/EMI filter for three-phase inverters and power drive systems
- Industry standard EMC solution for three-phase PDS filtering
- Slim space-saving book-style housing
- Solid safety connector blocks or optional wire output connections
- Excellent attenuation performance
- HV versions for up to 690VAC
- HVIT versions for IT distribution networks
- P/L versions with low leakage current
- Attenuation performance: high, very high
- Leakage current: 0.7 to 30 mA
- Motor power: 4 to 132 kW
- Operating frequency: dc to 60 Hz
- Rated Current: 7 to 250 A
- Voltage: ≤ 690 V
FN 3025 / FN 3026 Advanced EMC/EMI filter concept with minimum leakage current
- Compact state-of-the-art filter concept
- Light weight plastic enclosure design
- Minimized filter leakage current
- Hinged safety covers
- Revolutionary embedded filter terminals
- Chassis or DIN-rail mounting option
- Selectable performance level
- Environmental friendly design without potting compound
- Design protected by European patent (EP 1727280)
- Attenuation performance: standard
- Leakage current: 0.4 to 2.5 mA
- Motor power: 5.5 to 30 kW
- Operating frequency: dc to 60 Hz
- Rated Current: 10 to 50 A
- Voltage: ≤ 520 V
(Up to 150A)
FN 3100 EMC/EMI filter for regenerative motor drives
- Exceptional broadband attenuation performance from 10kHz up to 30MHz
- Equally suitable for conventional and regenerative motor drives (latter with additional line reactor only)
- Slim and user-friendly book-style design with touch-safe terminal blocks for minimum space and maximum safety
- Enables compliance with class B limits
- Attenuation performance: high, very high
- Leakage current: 48.9 to 71.5 mA
- Motor power: 22 to 160 kW
- Operating frequency: dc to 60 Hz
- Rated Current: 35 to 300 A
- Voltage: ≤ 520 V
FN 3120 High-end EMC/EMI filter for conventional and regenerative drives
- High performance filter for extremely noisy applications
- Ideal for the latest regenerative drives (with additional line-impedance)
- Significantly improves the reliability and immunity of installations
- Enables compliance with class B limits even with very long cables
- Attenuation performance: very high
- Leakage current: 97.9 mA
- Motor power: 15 to 132 kW
- Operating frequency: dc to 60 Hz
- Rated Current: 25 to 230 A
- Voltage: ≤ 520 V
FN 3258 Ultra-compact EMC/EMI filter for three-phase systems and motor drives
- New: solid safety connector blocks available for the whole range
- Exceptional attenuation performance from 150kHz to 30MHz
- Excellent saturation resistance up to 50m cable length
- Most compact and slim filter design in its class
- Attenuation performance: high, very high
- Leakage current: 33 mA
- Motor power: 4 to 110 kW
- Operating frequency: dc to 60 Hz
- Rated Current: 7 to 180 A
- Voltage: ≤ 520 V
FN 3268 Low-leakage current EMC/EMI filter for installations with RCD devices
- Full functionality with RCDs according to IEC 61008 and new VDE 0664-110
- Compatible with 30mA RCDs up to 30m motor cable for electric shock protection according to IEC 61008
- Compatible with 300mA RCDs up to 100m motor cable for fire protection according to IEC 60364-4-42 (VDE 0100-482)
- Attenuation performance: high, very high
- Leakage current: 4.5 to 37 mA
- Motor power: 4 to 110 kW
- Operating frequency: dc to 60 Hz
- Rated Current: 7 to 180 A
- Voltage: ≤ 520 V
FN 3270 Compact three-phase EMC/EMI filter for industrial motor drive applications
- Very compact and light weight design requiring minimum space
- Easy, time-saving installation and contacting
- Protective covers as optional accessory available
- Attenuation performance according to EN 61800-3/A11
- Attenuation performance: standard
- Leakage current: 26.4 to 59.5 mA
- Motor power: 5.5 to 560 kW
- Operating frequency: dc to 60 Hz
- Rated Current: 10 to 1000 A
- Voltage: ≤ 520 V
(Up to 1000A / c-UR-us: 600VAC)
FN 3359 High current three-phase EMC/EMI filter
- Off-the-shelf high power filter
- HV versions designed for 690VAC IT power networks
- Busbars for convenient and universal electrical connection
- Protective plastic covers optionally available for unsurpassed safety
- Attenuation performance: very high
- Leakage current: < 6 mA
- Motor power: 75 to 2000 kW
- Operating frequency: dc to 60 Hz
- Rated Current: 150 to 2500 A
- Voltage: ≤ 690 V
(FN 351 up to 110A: UR, CSA, ENEC / FN 351H up to 110A: c-CSA-us, ENEC)
FN 351 General purpose EMC/EMI filter for three-phase applications
- EMC solution for industrial inverters and motor drives
- Selectable voltage level of 440V and 520V
- High differential and common-mode attenuation
- Compliant with IEC 60950
- Attenuation performance: high
- Leakage current: 1.9 to 42.9 mA
- Motor power: 3 to 160 kW
- Operating frequency: dc to 60 Hz
- Rated Current: 8 to 280 A
- Voltage: ≤ 520 V
FN 3256 Compact three-phase and neutral line EMC/EMI filter for machinery/equipment
- Compact, space-saving design, optimized for industrial machinery
- Combines high attenuation performance with low leakage current
- Performance according to the machine tool standard EN 50370-1
- Increases also the immunity if operated directly on the mains input
- Attenuation performance: high
- Leakage current: < 1 mA
- Operating frequency: dc to 60 Hz
- Rated Current: 8 to 160 A
- Voltage: ≤ 520 V
FN 3280 High-end three-phase and neutral line EMC/EMI filter for machinery/equipment
- Compact, space-saving design, optimized for industrial machinery
- Combines exceptional attenuation with low leakage current
- Suitable for machines in mixed/domestic environments (Class A/B)
- Increases also the immunity if operated directly on the mains input
- Attenuation performance: very high
- Leakage current: < 1 mA
- Operating frequency: dc to 60 Hz
- Rated Current: 8 to 600 A
- Voltage: ≤ 520 V
FN 354 Compact three-phase and neutral line EMC/EMI filter for high frequency attenuation
- Compact four-wire filter for applications with limited space
- High attenuation performance up to 300MHz
- Equally suitable for star and delta power networks
- Attenuation performance: high
- Leakage current: 0.175 to 0.5 mA
- Operating frequency: dc to 60 Hz
- Rated Current: 4 to 25 A
- Voltage: ≤ 440 V
FN 355 Ultra-compact low leakage current 3-phase and neutral line EMC/EMI filter
- Ultra-compact four-wire filter for applications lacking space
- Exceptional low operating leakage current
- Equally suitable for star and delta power networks
- Attenuation performance: standard
- Leakage current: 0.07 to 0.29 mA
- Operating frequency: dc to 400 Hz
- Rated Current: 3 to 20 A
- Voltage: ≤ 440 V
(Up to 100A)
FN 356 General purpose three-phase and neutral line EMC/EMI filter
- Three-phase and neutral line filter for general four-wire filtering tasks
- Choice of connection style
- Low operating leakage current
- Compliant with IEC 60950
- Suitable to meet EN 55011/14/22
- Attenuation performance: high
- Leakage current: 0.43 to 8 mA
- Operating frequency: dc to 60 Hz
- Rated Current: 16 to 150 A
- Voltage: ≤ 440 V
RB series Common-mode chokes
- Rated currents from 16 to 50A
- Up to 600VAC or 1000VDC
- 2- and 3-wire configurations
- Horizontal and vertical PCB mounting types
- Ruggedized saturation and thermal behavior
- Open construction for forced and convection cooling
- Straightforward pin-out for easy PCB design
- Inductance: 0.2 to 3 mH
- Operating frequency: dc to 400 Hz
- Rated Current: 16 to 50 A
- Voltage: ≤ 600 VAC / 1000 VDC
FN 3410 ECOsine™ 50Hz Passive Harmonic Filters
- The industry standard for 6-pulse rectifiers and motor drives
- The most compact 5% THID filter available
- Excellent behavior under partial load conditions
- Filters for diode rectifiers
- Frequency: 50 Hz
- Harmonic mitigation: THID < 5%
- Rated Power: 4 to 200 kW
- Voltage: 380 to 500 V
FN 3410HV ECOsine™ 50Hz Passive Harmonic Filters for 690V
- The industry standard for 6-pulse rectifiers and motor drives
- The most compact 5% THID filter available
- Excellent behavior under partial load conditions
- Filters for diode rectifiers
- Frequency: 50 Hz
- Harmonic mitigation: THID < 5%
- Rated Power: 7.5 to 250 kW
- Voltage: 690 V
FN 3411 ECOsine™ 50Hz Passive Harmonic Filters
- The industry standard for 6-pulse rectifiers and motor drives
- Excellent behavior under partial load conditions
- Filters for thyristor (SCR) rectifiers
- Frequency: 50 Hz
- Harmonic mitigation: THID depending upon firing angle
- Rated Power: 4 to 200 kW
- Voltage: 380 to 500 V
FN 3411HV ECOsine™ 50Hz Passive Harmonic Filters for 690V
- The industry standard for 6-pulse rectifiers and motor drives
- Excellent behavior under partial load conditions
- Filters for thyristor (SCR) rectifiers
- Frequency: 50 Hz
- Harmonic mitigation: THID depending upon firing angle
- Rated Power: 7.5 to 250 kW
- Voltage: 690 V
FN 3412 ECOsine™ 60Hz Passive Harmonic Filters
- The industry standard for 6-pulse rectifiers and motor drives
- The most compact 5% THID filter available
- Excellent behavior under partial load conditions
- Filters for diode rectifiers
- Frequency: 60 Hz
- Harmonic mitigation: THID < 5%
- Rated Power: 5 to 250 HP
- Voltage: 380 to 480 V
FN 3413 ECOsine™ 60Hz Passive Harmonic Filters
- The industry standard for 6-pulse rectifiers and motor drives
- Excellent behavior under partial load conditions
- Filters for thyristor (SCR) rectifiers
- Frequency: 60 Hz
- Harmonic mitigation: THID depending upon firing angle
- Rated Power: 5 to 250 HP
- Voltage: 380 to 480 V
FN 3416 ECOsine™ Passive Harmonic Filters
- Economy line of passive harmonic
- filters for THID <10 %
- Help to comply with EN61000-3-12, IEEE-519 and other PQ standards
- Support an efficient utilization of electrical system capacity
- Ideal for motor drives with 6-pulse rectifier front-end
- Same filter for both diode and thyristor (SCR) rectifiers
- Frequency: 50 Hz
- Harmonic mitigation: THID < 10%
- Rated Power: 4 to 200 kW
- Voltage: 380 to 500 V
FN 3418 ECOsine™ Passive Harmonic Filters
- Economy line of passive harmonic filters for THID <10 %
- Help to comply with EN61000-3-12, IEEE-519 and other PQ standards
- Support an efficient utilization of electrical system capacity
- Ideal for motor drives with 6-pulse rectifier front-end
- Same filter for both diode and thyristor (SCR) rectifiers
- Frequency: 60 Hz
- Harmonic mitigation: THID < 10%
- Rated Power: 4 to 200 HP
- Voltage: 380 to 480 V
(30A to 100A UL recognized / 200A to 300A UL listed)
FN 3420 ECOsine™ Active Harmonic Filters (3-wire)
- Programmable harmonics mitigation, power factor correction, load balancing
- Ultra-fast electronics result in a response time of less than 300µs
- Adapts to changing network topologies instantly
- Filters for up to 480V 3-wire networks
- Compensation current: 30 to 300 A
- Frequency: 47 to 63 Hz
- Harmonic mitigation: THID < 5%,THID adjustable
- Voltage: 200 to 480 V
FN 3430 ECOsine™ Active Harmonic Filters (4-wire)
- Programmable harmonics mitigation, power factor correction, load balancing
- Ultra-fast electronics result in a response time of less than 300µs
- Adapts to changing network topologies instantly
- Filters for 400V 4-wire networks
- Compensation current: 30 to 300 A
- Frequency: 47 to 63 Hz
- Harmonic mitigation: THID < 5%,THID adjustable
- Voltage: 380 to 415 V
(on request)
Compact and user-friendly combination of transformer and reactor
- Combination of insulation, step-up or step-down transformer and smoothing- or filter-reactor
- Possibility to customize most electrical and mechanical parameters
- Reduction in overall weight and volume
- Reduction in installation time
- Simplification of the power structure
- Reduction in total cost of ownership
- Frequency: 50 to 60 Hz
- Harmonic mitigation: All
RWK 212 Three-phase line reactor for motor drive applications
- Reduction of mains harmonics
- Reduction of commutation notches
- Protection of motor drive electronics
- Limitation of inrush currents
- Improvement of true power factor
- Frequency: 50 to 60 Hz
- Harmonic mitigation: THID appr. 40%
- Impedance: 4 % @ 400 VAC, 50 Hz & rated current
- Motor power: 1.5 to 630 kW
- Rated Current: 4 to 1100 A
- Voltage: ≤ 500 V
FN 5020 Sine wave output filter for high-speed motor drives
- Smoothing of PWM drive output voltages
- Increased service life of expensive high-speed motors
- Reduction of audible motor noise
- Improvement of system reliability
- Production up-time for mission critical applications
- Harmonic mitigation: All
- Motor cable length: ≤200m
- Motor frequency: 0 to 600 Hz
- Motor power: 15 to 75 kW
- Rated Current: 25 to 120 A
- Switching Frequency: 6 to 15 kHz
- Voltage: 0 to 500 V
FN 5030 Add-on common mode module for sine wave output filter
- Additional module for use with FN 5020 sine wave filters only
- Reduction of common-mode interferences on motor cables
- Improvement of EMC environment
- Elimination of motor bearing damages
- Possibility to use very long unshielded motor cables
- Improvement of system reliability
- Harmonic mitigation: All
- Motor cable length: ≤1000m
- Motor frequency: 0 to 600 Hz
- Motor power: 15 to 75 kW
- Rated Current: 25 to 120 A
- Switching Frequency: 6 to 15 kHz
- Voltage: 0 to 500 V
FN 5040 / FN 5045 LC sine wave filter for motor drives
- Smooth sine wave without voltage peaks
- Perfect motor protection
- Reduce bearing currents
- Motor frequency up to 200Hz
- Extended motor cable lenght capability
- Harmonic mitigation: All
- Motor cable length: ≤2000m
- Motor frequency: 0 to 70 Hz
- Motor power: 1.1 to 630 kW
- Rated Current: 4.5 to 1200 A
- Switching Frequency: 2 to 12 kHz
- Voltage: 0 to 500 V
FN 5040 HV Sine wave filter for 690 VAC motor drives applications
- Smooth sine wave without voltage peaks
- Motor protection against pulse pattern stress
- Improvement of system reliability
- Reduces bearing currents
- Ideal for retrofit installations
- Fits for long motor cable lengths (≤ 2000 m)
- Motor drive power range up to 1,200 kW
- Motor cable length: ≤2000m
- Motor frequency: 0 to 70 Hz
- Motor power: 7.5 to 1200 kW
- Rated Current: 13 to 1320 A
- Switching Frequency: 2 to 16 kHz
- Voltage: 0 to 690 V
FN 510 Output filter for motor drives
- Reduction of drive output voltage dv/dt
- Restriction of overvoltages on motor cables
- Reduction of motor temperature
- Increase of motor service life
- Improvement of system reliability
- Harmonic mitigation: All
- Motor cable length: ≤80m
- Motor frequency: 0 to 400 Hz
- Motor power: 1.5 to 30 kW
- Rated Current: 4 to 66 A
- Switching Frequency: 2 to 16 kHz
- Voltage: 380 to 500 V
FN 530 Sine wave and EMC output filter for motor drives with a voltage dc link
- Smoothing of PWM drive output voltage
- Efficient motor protection
- Reduction of common-mode interferences on motor cables
- Improvement of EMC environment
- Elimination of motor bearing damages
- Possibility to use very long unshielded motor cables
- Improvement of system reliability
- Harmonic mitigation: All
- Motor cable length: ≤1000m
- Motor frequency: 0 to 200 Hz
- Motor power: 1.5 to 7.5 kW
- Rated Current: 4 to 16 A
- Switching Frequency: 6 to 20 kHz
- Voltage: 0 to 520 V
RWK 305 Three-phase dv/dt reactor for efficient motor protection
- Reduction of drive output voltage dv/dt
- Reduction of motor temperature
- Increase of motor service life
- Compact and economic open frame design
- Standard catalog reactors up to 1100A
- UL rated materials used
- Harmonic mitigation: All
- Motor cable length: ≤50m
- Motor frequency: 0 to 60 Hz
- Motor power: 1.5 to 630 kW
- Rated Current: 4 to 1100 A
- Switching Frequency: 2 to 16 kHz
- Voltage: 380 to 500 V
Product Search
08.04.2013