Products: 8
FN 9222 General performance IEC inlet filter

FN 9222 General performance IEC inlet filter

  • Excellent performance/size ratio
  • Optional medical versions (B type)
  • Snap-in versions (S and S1 type)
  • Hot inlet versions (HI type)
  • Optional overvoltage protection (Z type)
  • Attenuation performance: standard
  • Frequency: dc to 400 Hz
  • Leakage current: 373 µA
  • Leakage current (B types): 2 µA
  • Rated Current: 1 to 20 A
  • Voltage: ≤ 250 V
  • Compliant IEC/EN 60601-1
  •  
  •  
  •  
  •  
  •  
  •  
  •  
FN 9222E General performance IEC inlet filter with earth line choke
(CQC approval pending)

FN 9222E General performance IEC inlet filter with earth line choke

  • Excellent performance/size ratio
  • Integrated earth line choke
  • Optional medical versions (B type)
  • Snap-in versions (S and S1 type)
  • Optional wide mounting flanges
  • Attenuation performance: standard
  • Frequency: dc to 400 Hz
  • Leakage current: 373 µA
  • Leakage current (B types): 2 µA
  • Rated Current: 1 to 15 A
  • Voltage: ≤ 250 V
  • Compliant IEC/EN 60601-1
  •  
  •  
  •  
  •  
  •  
  •  
  •  
FN 9226 HF performance IEC inlet filter

FN 9226 HF performance IEC inlet filter

  • Faston connection
  • Optional PCB through hole connection
  • Good HF coupling to the equipment housing
  • Optional medical versions (B type)
  • Attenuation performance: standard
  • Frequency: dc to 400 Hz
  • Leakage current: 373 µA
  • Leakage current (B types): 2 µA
  • Rated Current: 1 to 10 A
  • Voltage: ≤ 250 V
  •  
  •  
  •  
  •  
  •  
  •  
FN 9233 High performance IEC inlet filter
(CQC approval pending)

FN 9233 High performance IEC inlet filter

  • Excellent attenuation performance
  • Optional earth line choke
  • Optional medical versions (B type)
  • Snap-in versions (S and S1 type)
  • Hot inlet versions (HI type)
  • Attenuation performance: standard,high
  • Frequency: dc to 400 Hz
  • Leakage current: 373 µA
  • Leakage current (B types): 2 µA
  • Rated Current: 1 to 15 A
  • Voltage: ≤ 250 V
  • Compliant IEC/EN 60601-1
  •  
  •  
  •  
  •  
  •  
  •  
  •  
FN 9233E High performance IEC inlet filter with earth line choke
(CQC approval pending)

FN 9233E High performance IEC inlet filter with earth line choke

  • Excellent attenuation performance
  • Integrated earth line choke
  • Optional medical versions (B type)
  • Snap-in versions (S and S1 type)
  • Hot inlet versions (HI type)
  • Attenuation performance: high,very high
  • Frequency: dc to 400 Hz
  • Leakage current: 373 µA
  • Leakage current (B types): 2 µA
  • Rated Current: 1 to 15 A
  • Voltage: ≤ 250 V
  • Compliant IEC/EN 60601-1
  •  
  •  
  •  
  •  
  •  
  •  
  •  
FN 9244 Excellent performance IEC inlet filter
(CQC approval pending)

FN 9244 Excellent performance IEC inlet filter

  • Superior attenuation performance
  • Optional earth line choke
  • Optional medical versions (B type)
  • Snap-in versions (S and S1 type)
  • Hot inlet versions (HI type)
  • Attenuation performance: very high
  • Frequency: dc to 400 Hz
  • Leakage current: 373 µA
  • Leakage current (B types): 2 µA
  • Rated Current: 1 to 15 A
  • Voltage: ≤ 250 V
  • Compliant IEC/EN 60601-1
  •  
  •  
  •  
  •  
  •  
  •  
  •  
FN 9244E Excellent performance IEC inlet filter with earth line choke
(CQC approval pending)

FN 9244E Excellent performance IEC inlet filter with earth line choke

  • Superior attenuation performance
  • Integrated earth line choke
  • Optional medical versions (B type)
  • Snap-in versions (S and S1 type)
  • Hot inlet versions (HI type)
  • Attenuation performance: very high
  • Frequency: dc to 400 Hz
  • Leakage current: 373 µA
  • Leakage current (B types): 2 µA
  • Rated Current: 1 to 15 A
  • Voltage: ≤ 250 V
  • Compliant IEC/EN 60601-1
  •  
  •  
  •  
  •  
  •  
  •  
  •  
FN 9246 High performance IEC inlet filter

FN 9246 High performance IEC inlet filter

  • Optional medical versions (B type)
  • Attenuation performance: high
  • Frequency: dc to 400 Hz
  • Leakage current: 373 to 797 µA
  • Leakage current (B types): 2 µA
  • Rated Current: 1 to 20 A
  • Voltage: ≤ 250 V
  •  
  •  
  •  
  •  
  •  
  •  

Configurator

 -   V
Choose Voltage
 -   A
Choose Current
 -   
Choose Attenuation performance

Categories

Downloads

03.05.2012

UL-Approval for Sinusoidal Filters FN5040/45