Products: 16
IL13 Power cord with Locking System for IEC inlet filters with C14 inlet

IL13 Power cord with Locking System for IEC inlet filters with C14 inlet

  • Power cord with locking system for IEC inlets
  • No accidental disconnection
  • Fits any Schaffner IEC C14 inlet filter
  • Retrofit for any electronic equipment with IEC C14 inlet
  • Various power line plugs for international usage
  • Color: black
  • Connector line side: C14; CEE7/VII; BS1363; NEMA5-15; SEV1011
  • Connector load side: C13 with lock
  • Frequency: 50/60 Hz
  • Length: 2 m
  • Rated Current: 10 A
  • Voltage: ≤ 250 V
  •  
  •  
  •  
  •  
  •  
  •  
  •  
FN 9222 General performance IEC inlet filter

FN 9222 General performance IEC inlet filter

  • Excellent performance/size ratio
  • Optional medical versions (B type)
  • Snap-in versions (S and S1 type)
  • Hot inlet versions (HI type)
  • Optional overvoltage protection (Z type)
  • Attenuation performance: standard
  • Frequency: dc to 400 Hz
  • Leakage current: 373 µA
  • Leakage current (B types): 2 µA
  • Rated Current: 1 to 20 A
  • Voltage: ≤ 250 V
  • Compliant IEC/EN 60601-1
  •  
  •  
  •  
  •  
  •  
  •  
  •  
FN 9222E General performance IEC inlet filter with earth line choke
(CQC approval pending)

FN 9222E General performance IEC inlet filter with earth line choke

  • Excellent performance/size ratio
  • Integrated earth line choke
  • Optional medical versions (B type)
  • Snap-in versions (S and S1 type)
  • Optional wide mounting flanges
  • Attenuation performance: standard
  • Frequency: dc to 400 Hz
  • Leakage current: 373 µA
  • Leakage current (B types): 2 µA
  • Rated Current: 1 to 15 A
  • Voltage: ≤ 250 V
  • Compliant IEC/EN 60601-1
  •  
  •  
  •  
  •  
  •  
  •  
  •  
FN 9226 HF performance IEC inlet filter

FN 9226 HF performance IEC inlet filter

  • Faston connection
  • Optional PCB through hole connection
  • Good HF coupling to the equipment housing
  • Optional medical versions (B type)
  • Attenuation performance: standard
  • Frequency: dc to 400 Hz
  • Leakage current: 373 µA
  • Leakage current (B types): 2 µA
  • Rated Current: 1 to 10 A
  • Voltage: ≤ 250 V
  •  
  •  
  •  
  •  
  •  
  •  
FN 9233 High performance IEC inlet filter
(CQC approval pending)

FN 9233 High performance IEC inlet filter

  • Excellent attenuation performance
  • Optional earth line choke
  • Optional medical versions (B type)
  • Snap-in versions (S and S1 type)
  • Hot inlet versions (HI type)
  • Attenuation performance: standard,high
  • Frequency: dc to 400 Hz
  • Leakage current: 373 µA
  • Leakage current (B types): 2 µA
  • Rated Current: 1 to 15 A
  • Voltage: ≤ 250 V
  • Compliant IEC/EN 60601-1
  •  
  •  
  •  
  •  
  •  
  •  
  •  
FN 9233E High performance IEC inlet filter with earth line choke
(CQC approval pending)

FN 9233E High performance IEC inlet filter with earth line choke

  • Excellent attenuation performance
  • Integrated earth line choke
  • Optional medical versions (B type)
  • Snap-in versions (S and S1 type)
  • Hot inlet versions (HI type)
  • Attenuation performance: high,very high
  • Frequency: dc to 400 Hz
  • Leakage current: 373 µA
  • Leakage current (B types): 2 µA
  • Rated Current: 1 to 15 A
  • Voltage: ≤ 250 V
  • Compliant IEC/EN 60601-1
  •  
  •  
  •  
  •  
  •  
  •  
  •  
FN 9244 Excellent performance IEC inlet filter
(CQC approval pending)

FN 9244 Excellent performance IEC inlet filter

  • Superior attenuation performance
  • Optional earth line choke
  • Optional medical versions (B type)
  • Snap-in versions (S and S1 type)
  • Hot inlet versions (HI type)
  • Attenuation performance: very high
  • Frequency: dc to 400 Hz
  • Leakage current: 373 µA
  • Leakage current (B types): 2 µA
  • Rated Current: 1 to 15 A
  • Voltage: ≤ 250 V
  • Compliant IEC/EN 60601-1
  •  
  •  
  •  
  •  
  •  
  •  
  •  
FN 9244E Excellent performance IEC inlet filter with earth line choke
(CQC approval pending)

FN 9244E Excellent performance IEC inlet filter with earth line choke

  • Superior attenuation performance
  • Integrated earth line choke
  • Optional medical versions (B type)
  • Snap-in versions (S and S1 type)
  • Hot inlet versions (HI type)
  • Attenuation performance: very high
  • Frequency: dc to 400 Hz
  • Leakage current: 373 µA
  • Leakage current (B types): 2 µA
  • Rated Current: 1 to 15 A
  • Voltage: ≤ 250 V
  • Compliant IEC/EN 60601-1
  •  
  •  
  •  
  •  
  •  
  •  
  •  
FN 9246 High performance IEC inlet filter

FN 9246 High performance IEC inlet filter

  • Optional medical versions (B type)
  • Attenuation performance: high
  • Frequency: dc to 400 Hz
  • Leakage current: 373 to 797 µA
  • Leakage current (B types): 2 µA
  • Rated Current: 1 to 20 A
  • Voltage: ≤ 250 V
  •  
  •  
  •  
  •  
  •  
  •  
FN 9260 General purpose power entry module with fuses

FN 9260 General purpose power entry module with fuses

  • For one or two fuses
  • Optional safety version (A type)
  • Optional medical versions (B type)
  • Snap-in versions (S type)
  • Attenuation performance: standard
  • Frequency: dc to 400 Hz
  • Leakage current: 373 µA
  • Rated Current: 1 to 10 A
  • Voltage: ≤ 250 V
  •  
  •  
  •  
  •  
  •  
FN 9263 General purpose power entry module with mains switch
(CQC approval pending)

FN 9263 General purpose power entry module with mains switch

  • 1-pole rocker switch
  • Snap-in versions (S and S1 type)
  • Compact to fit 1U rack size
  • Attenuation performance: standard
  • Frequency: 50 to 400 Hz
  • Leakage current: 373 µA
  • Rated Current: 1 to 10 A
  • Voltage: ≤ 250 V
  •  
  •  
  •  
  •  
  •  
FN 9264 Compact power entry module
(CQC approval pending)

FN 9264 Compact power entry module

  • Compact size
  • Complies with IEC/EN 60601
  • High quality 2-pole rocker switch
  • Good attenuation performance
  • Attenuation performance: high
  • Frequency: 50 to 400 Hz
  • Leakage current: 373 µA
  • Rated Current: 1 to 10 A
  • Voltage: ≤ 250 V
  •  
  •  
  •  
  •  
  •  
FN 280 Compact filtered power entry module

FN 280 Compact filtered power entry module

  • Single or dual-fuse holder
  • Fuses Ø5 x 20mm
  • 2-pole rocker switch
  • General purpose application
  • Optional earth line choke (E type)
  • Optional medical versions (B type)
  • Attenuation performance: standard
  • Frequency: 50 to 400 Hz
  • Leakage current: 373 µA
  • Leakage current (B types): 2 µA
  • Rated Current: 1 to 10 A
  • Voltage: ≤ 250 V
  •  
  •  
  •  
  •  
  •  
  •  
FN 370 Versatile filtered power entry module

FN 370 Versatile filtered power entry module

  • Single or dual-fuse holder
  • Fuses Ø6.3 x 32mm or Ø5 x 20mm
  • Voltage selector 100/120/230/240V
  • General purpose application
  • Optional medical versions (B type)
  • Attenuation performance: standard
  • Frequency: dc to 400 Hz
  • Leakage current: 373 µA
  • Leakage current (B types): 2 µA
  • Rated Current: 2 to 6 A
  • Voltage: ≤ 250 V
  •  
  •  
  •  
  •  
  •  
  •  
FN 380 Versatile filtered power entry module

FN 380 Versatile filtered power entry module

  • Single or dual-fuse holder
  • Fuses Ø6.3 x 32mm Ø5 x 20mm
  • 2-pole rocker switch
  • General purpose application
  • Optional medical versions (B type)
  • Attenuation performance: standard
  • Frequency: 50 to 400 Hz
  • Leakage current: 373 µA
  • Leakage current (B types): 2 µA
  • Rated Current: 2 to 6 A
  • Voltage: ≤ 250 V
  •  
  •  
  •  
  •  
  •  
  •  
FN 390 Versatile filtered power entry module

FN 390 Versatile filtered power entry module

  • For one or two fuses
  • Fuses Ø6.3 x 32mm or Ø5 x 20mm
  • 2-pole rocker switch
  • Voltage selector
  • Optional earth line choke (E type)
  • Attenuation performance: high
  • Frequency: 50 to 400 Hz
  • Leakage current: 560 to 797 µA
  • Rated Current: 1 to 10 A
  • Voltage: ≤ 250 V
  •  
  •  
  •  
  •  
  •  