Products: 19
IL13 Power cord with Locking System for IEC inlet filters with C14 inlet
- Power cord with locking system for IEC inlets
- No accidental disconnection
- Fits any Schaffner IEC C14 inlet filter
- Retrofit for any electronic equipment with IEC C14 inlet
- Various power line plugs for international usage
- Color: black
- Connector line side: C14; CEE7/VII; BS1363; NEMA5-15; SEV1011; JIS8303
- Connector load side: C13 with IEC lock
- Frequency: 50/60 Hz
- Length: 2 m
- Operating frequency: dc to 60 Hz
- Rated Current: 10 A
- Voltage: ≤ 250 V
IL19 Power cord with Locking System for IEC inlet filters with C20 inlet
- Power cord with locking system for IEC inlets
- No accidental disconnection
- Fits any Schaffner IEC C20 inlet filter
- Retrofit for any electronic equipment with IEC C20 inlet
- Various power line plugs for international usage
- Color: black
- Connector line side: C20; CEE7/VII; BS1363; NEMA5-15
- Connector load side: C19 with IEC Lock
- Rated Current: 16 A
- Voltage: ≤ 250 V
FN 9222 General performance IEC inlet filter
- Excellent performance/size ratio
- Optional medical versions (B type)
- Snap-in versions (S and S1 type)
- Hot inlet versions (HI type)
- Optional overvoltage protection (Z type)
- Attenuation performance: standard
- Leakage current: 373 µA
- Leakage current (B types): 2 µA
- Operating frequency: dc to 400 Hz
- Rated Current: 1 to 20 A
- Voltage: ≤ 250 V
- Compliant IEC/EN 60601-1
(CQC approval pending)
FN 9222E General performance IEC inlet filter with earth line choke
- Excellent performance/size ratio
- Integrated earth line choke
- Optional medical versions (B type)
- Snap-in versions (S and S1 type)
- Optional wide mounting flanges
- Attenuation performance: standard
- Leakage current: 373 µA
- Leakage current (B types): 2 µA
- Operating frequency: dc to 400 Hz
- Rated Current: 1 to 15 A
- Voltage: ≤ 250 V
- Compliant IEC/EN 60601-1
FN 9226 HF performance IEC inlet filter
- Faston connection
- Optional PCB through hole connection
- Good HF coupling to the equipment housing
- Optional medical versions (B type)
- Attenuation performance: standard
- Leakage current: 373 µA
- Leakage current (B types): 2 µA
- Operating frequency: dc to 400 Hz
- Rated Current: 1 to 10 A
- Voltage: ≤ 250 V
(CQC approval pending)
FN 9233 High performance IEC inlet filter
- Excellent attenuation performance
- Optional earth line choke
- Optional medical versions (B type)
- Snap-in versions (S and S1 type)
- Hot inlet versions (HI type)
- Attenuation performance: standard, high
- Leakage current: 373 µA
- Leakage current (B types): 2 µA
- Operating frequency: dc to 400 Hz
- Rated Current: 1 to 15 A
- Voltage: ≤ 250 V
- Compliant IEC/EN 60601-1
(CQC approval pending)
FN 9233E High performance IEC inlet filter with earth line choke
- Excellent attenuation performance
- Integrated earth line choke
- Optional medical versions (B type)
- Snap-in versions (S and S1 type)
- Hot inlet versions (HI type)
- Attenuation performance: high, very high
- Leakage current: 373 µA
- Leakage current (B types): 2 µA
- Operating frequency: dc to 400 Hz
- Rated Current: 1 to 15 A
- Voltage: ≤ 250 V
- Compliant IEC/EN 60601-1
(CQC approval pending)
FN 9244 Excellent performance IEC inlet filter
- Superior attenuation performance
- Optional earth line choke
- Optional medical versions (B type)
- Snap-in versions (S and S1 type)
- Hot inlet versions (HI type)
- Attenuation performance: very high
- Leakage current: 373 µA
- Leakage current (B types): 2 µA
- Operating frequency: dc to 400 Hz
- Rated Current: 1 to 15 A
- Voltage: ≤ 250 V
- Compliant IEC/EN 60601-1
(CQC approval pending)
FN 9244E Excellent performance IEC inlet filter with earth line choke
- Superior attenuation performance
- Integrated earth line choke
- Optional medical versions (B type)
- Snap-in versions (S and S1 type)
- Hot inlet versions (HI type)
- Attenuation performance: very high
- Leakage current: 373 µA
- Leakage current (B types): 2 µA
- Operating frequency: dc to 400 Hz
- Rated Current: 1 to 15 A
- Voltage: ≤ 250 V
- Compliant IEC/EN 60601-1
FN 9260 General purpose power entry module with fuses
- For one or two fuses
- Optional safety version (A type)
- Optional medical versions (B type)
- Snap-in versions (S type)
- Attenuation performance: standard
- Leakage current: 373 µA
- Operating frequency: dc to 400 Hz
- Operating frequency: dc to 400 Hz
- Rated Current: 1 to 10 A
- Voltage: ≤ 250 V
(CQC approval pending)
FN 9263 General purpose power entry module with mains switch
- 1-pole rocker switch
- Snap-in versions (S and S1 type)
- Compact to fit 1U rack size
- Attenuation performance: standard
- Frequency: 50 to 400 Hz
- Leakage current: 373 µA
- Operating frequency: dc to 400 Hz
- Rated Current: 1 to 10 A
- Voltage: ≤ 250 V
(CQC approval pending)
FN 9264 Compact power entry module
- Compact size
- Complies with IEC/EN 60601
- High quality 2-pole rocker switch
- Good attenuation performance
- Attenuation performance: high
- Frequency: 50 to 400 Hz
- Leakage current: 373 µA
- Operating frequency: dc to 400 Hz
- Rated Current: 1 to 10 A
- Voltage: ≤ 250 V
FN 280 Compact filtered power entry module
- Rated currents up to 10A
- Single or dual-fuse holder
- Fuses Ø5 x 20mm
- 2-pole rocker switch
- General purpose application
- Optional earth line choke (E type)
- Optional medical versions (B type)
- Attenuation performance: standard
- Frequency: 50 to 400 Hz
- Leakage current: 373 µA
- Leakage current (B types): 2 µA
- Operating frequency: dc to 400 Hz
- Rated Current: 1 to 10 A
- Voltage: ≤ 250 V
FN 370 Versatile filtered power entry module
- Single or dual-fuse holder
- Fuses Ø6.3 x 32mm or Ø5 x 20mm
- Voltage selector 100/120/230/240V
- General purpose application
- Optional medical versions (B type)
- Attenuation performance: standard
- Leakage current: 373 µA
- Leakage current (B types): 2 µA
- Operating frequency: dc to 400 Hz
- Rated Current: 2 to 6 A
- Voltage: ≤ 250 V
FN 380 Versatile filtered power entry module
- Single or dual-fuse holder
- Fuses Ø6.3 x 32mm Ø5 x 20mm
- 2-pole rocker switch
- General purpose application
- Optional medical versions (B type)
- Attenuation performance: standard
- Frequency: 50 to 400 Hz
- Leakage current: 373 µA
- Leakage current (B types): 2 µA
- Operating frequency: dc to 400 Hz
- Rated Current: 2 to 6 A
- Voltage: ≤ 250 V
FN 390 Versatile filtered power entry module
- For one or two fuses
- Fuses Ø6.3 x 32mm or Ø5 x 20mm
- 2-pole rocker switch
- Voltage selector
- Optional earth line choke (E type)
- Attenuation performance: high
- Frequency: 50 to 400 Hz
- Leakage current: 560 to 797 µA
- Operating frequency: dc to 400 Hz
- Rated Current: 1 to 10 A
- Voltage: ≤ 250 V
(CQC, approval pending)
FN 9280 Ultra compact and versatile filtered single stage power entry module
- dual-fuse holder
- Fuses Ø5x20mm
- 2-pole rocker switch
- General purpose application
- Optional earth line choke (E type)
- Optional medical version (B type)
- Attenuation performance: high
- Frequency: 50 to 400 Hz
- Leakage current medical (B types): < 5 µA
- Leakage current standard: < 500 µA
- Operating frequency: dc to 400 Hz
- Rated Current: 1 to 10 A
- Voltage: ≤ 250 V
(CQC, approval pending)
FN 9290 Ultra compact and versatile filtered dual stage power entry module
- dual-fuse holder
- Fuses Ø5x20mm
- 2-pole rocker switch
- high noise level application
- Optional medical versions (B type)
- Attenuation performance: very high
- Frequency: 50 to 400 Hz
- Leakage current medical (B types): < 5 µA
- Leakage current standard: < 500 µA
- Operating frequency: dc to 400 Hz
- Rated Current: 1 to 10 A
- Voltage: ≤ 250 V
Configurator
Categories
Downloads
08.04.2013